Requirements#
Classic Diagnostic Adapter Requirements
|
status: draft
security: YES
safety: QM
|
||||
Functional Requirements#
CDA HTTP Server Port
|
status: valid
security: YES
safety: QM
|
||||
The classic diagnostic adapter shall serve its SOVD API on the HTTP or HTTPS port set in its configuration. Refines req~sovd-api-http-server-port. |
|||||
CDA Faults Endpoint
|
status: valid
security: YES
safety: QM
|
||||
The classic diagnostic adapter shall, for each ECU:
Refines req~sovd-api-faults-endpoint. |
|||||
CDA Asynchronous Operations
|
status: valid
security: YES
safety: QM
|
||||
For an ECU routine that defines the
Refines req~sovd-api-operations-handling. |
|||||
CDA ECU Lock
|
status: valid
security: YES
safety: QM
|
||||
The classic diagnostic adapter shall let a client acquire a lock on an ECU at
Refines req~sovd-api-lock-api. |
|||||
CDA ECU Lock Enforcement
|
status: valid
security: YES
safety: QM
|
||||
The classic diagnostic adapter shall reject a write request to an ECU, such as clearing its faults, with HTTP 409 and leave the ECU unchanged when no lock is held on the ECU, and shall execute the request when the client holds a lock on the ECU. Refines req~sovd-api-lock-ecu-enforcement. |
|||||
CDA UDS Service Mapping
|
status: valid
security: YES
safety: QM
|
||||
The classic diagnostic adapter shall translate the following SOVD resources of an ECU into the UDS services of that ECU:
Refines req~sovd-api-standardized-resource-collection-mapping. |
|||||