Root Causes#

Coverage: 37.0% (60 of 162 items OK)

[PARTIAL] TRLC Rootcause mw_com_fta.BindingSelectionFaulty
[PARTIAL] TRLC Rootcause mw_com_fta.CallSignalledBeforeInArgsCompletelyProvided

Call signalled before InArgs completely provided


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:80:20

[PARTIAL] TRLC Rootcause mw_com_fta.CalledEventhoughStopfindserviceHasBeenCalled
[PARTIAL] TRLC Rootcause mw_com_fta.CalledReduandently
[PARTIAL] TRLC Rootcause mw_com_fta.CalleeConcurrentlyUpdatesResultAfterSignaling

Callee concurrently updates result after signaling it


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:120:20

[PARTIAL] TRLC Rootcause mw_com_fta.CalleeProvidedResultInWrongLayout

Callee provided result in wrong layout


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:128:20

[PARTIAL] TRLC Rootcause mw_com_fta.CalleeProvidedResultInWrongLocation

Callee provided result in wrong location


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:136:20

[PARTIAL] TRLC Rootcause mw_com_fta.CalleeSignalledCallFinishedBeforeResultComplete

Callee signalled call finished before or without providing result completely


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:144:20

[PARTIAL] TRLC Rootcause mw_com_fta.CalleeUsedInArgsBeforeBeingProvided

Callee used InArgs before being provided


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:152:20

[PARTIAL] TRLC Rootcause mw_com_fta.CalleeUsedInArgsFromWrongLocation

Callee used InArgs from wrong location


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:160:20

[PARTIAL] TRLC Rootcause mw_com_fta.CalleeUsedInArgsInWrongLayout

Callee used InArgs in wrong layout


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:168:20

[PARTIAL] TRLC Rootcause mw_com_fta.CalleeUsedInArgsWhileConcurrentlyUpdated

Callee used InArgs while concurrently updated


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:176:20

[PARTIAL] TRLC Rootcause mw_com_fta.CallerProvidedInArgsInWrongLocation

Caller provided InArgs in wrong location


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:184:20

[PARTIAL] TRLC Rootcause mw_com_fta.CallerUsedResultBeforeFullyProvided

Caller used result before fully provided


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:192:20

[PARTIAL] TRLC Rootcause mw_com_fta.CallerUsedResultFromWrongLocation

Caller used result from wrong location


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:200:20

[PARTIAL] TRLC Rootcause mw_com_fta.CallerUsedResultInWrongLayout

Caller used result in wrong layout


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:208:20

[PARTIAL] TRLC Rootcause mw_com_fta.CallerUsedResultWhileConcurrentlyUpdated

Caller used result while concurrently updated


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:216:20

[PARTIAL] TRLC Rootcause mw_com_fta.ChangingStateFails
[PARTIAL] TRLC Rootcause mw_com_fta.ConsumerLookedUpSizeInWrongLocation
[PARTIAL] TRLC Rootcause mw_com_fta.CopyOnSendDoesNotDestroySampleallocateeptr

Copy on send does not destroy SampleAllocateePtr


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:248:20

[PARTIAL] TRLC Rootcause mw_com_fta.CounterOfInvokedCallbacksIsWrong

The counter of invoked callbacks is wrong


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:256:20

[PARTIAL] TRLC Rootcause mw_com_fta.DependentPrepareOfferFailed

PrepareOffer on dependent elements failed


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:272:20

[PARTIAL] TRLC Rootcause mw_com_fta.DependentPrepareOfferNotCalled

PrepareOffer on dependent elements not called


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:280:20

[PARTIAL] TRLC Rootcause mw_com_fta.DestructionOfSampleallocateeptrDoesNotTriggerStateChange

Destruction of SampleAllocateePtr does not trigger state change


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:288:20

[PARTIAL] TRLC Rootcause mw_com_fta.DifferentlyConfiguredBetweenSkletonAndProxySide

Differently configured between skleton and proxy side


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:304:20

[PARTIAL] TRLC Rootcause mw_com_fta.DirectAccessToDataViaAllocateePtr
[PARTIAL] TRLC Rootcause mw_com_fta.DirectAccessToDataViaCopy
[PARTIAL] TRLC Rootcause mw_com_fta.DoesNotFreeMethodSignatureElement

Does not free method signature element


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:328:20

[PARTIAL] TRLC Rootcause mw_com_fta.EventFieldIdReferencesWrongStorage
[PARTIAL] TRLC Rootcause mw_com_fta.EventFieldNameMappingClash
[PARTIAL] TRLC Rootcause mw_com_fta.EventInstanceAPICalledInAReentrantManner

Event instance API called in a reentrant manner


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:352:20

[PARTIAL] TRLC Rootcause mw_com_fta.ExplicitUnsubscribeByUserFailed

Explicit unsubscribe by user failed


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:368:20

[PARTIAL] TRLC Rootcause mw_com_fta.FilenameCreationFromConfigFailed

Filename creation from config failed


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:384:20

[PARTIAL] TRLC Rootcause mw_com_fta.GenericTraceapiChangesData
[PARTIAL] TRLC Rootcause mw_com_fta.InArgsCorruptedBy3rdParty

InArgs corrupted by 3d party


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:424:20

[PARTIAL] TRLC Rootcause mw_com_fta.InArgsUpdateAfterCall

Caller updates InArgs concurrently after call signalling


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:432:20

[PARTIAL] TRLC Rootcause mw_com_fta.InArgsWrongLayout

Caller provided InArgs in wrong layout


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:440:20

[PARTIAL] TRLC Rootcause mw_com_fta.IncreasingDecreasingRefCountFails
[PARTIAL] TRLC Rootcause mw_com_fta.IndicationWhetherFormatIsSerializedWronglyImplemented
[PARTIAL] TRLC Rootcause mw_com_fta.InotifyReturnsWrongInformation
[PARTIAL] TRLC Rootcause mw_com_fta.InstanceSpecifierResolutionBrokenNotOffered

Instance Specifier resolution broken


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:472:20

[PARTIAL] TRLC Rootcause mw_com_fta.InstanceSpecifierResolutionBrokenWrongBinding

Instance Specifier resolution broken


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:480:20

[PARTIAL] TRLC Rootcause mw_com_fta.InstanceSpecifierResolutionFaulty

Instance Specifier resolution faulty


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:488:20

[PARTIAL] TRLC Rootcause mw_com_fta.InstancespecifierResolvedToWrongInstanceidentifier

InstanceSpecifier resolved to wrong InstanceIdentifier


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:504:20

[PARTIAL] TRLC Rootcause mw_com_fta.LifeCycleIssuesElementPtr
[PARTIAL] TRLC Rootcause mw_com_fta.MessagePassingCorruptsTheMaxSampleValue

Message passing corrupts the max. sample value


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:576:20

[PARTIAL] TRLC Rootcause mw_com_fta.MethodIdCorrupted
[PARTIAL] TRLC Rootcause mw_com_fta.NoUnmapOnDestruction
[PARTIAL] TRLC Rootcause mw_com_fta.NotAllEventsArePopulated
[PARTIAL] TRLC Rootcause mw_com_fta.NotCreatedAtAll
[PARTIAL] TRLC Rootcause mw_com_fta.OfferCallDidNotCheckIfUserProvidedFieldValues

Offer call did not check, if user provided field values


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:648:20

[PARTIAL] TRLC Rootcause mw_com_fta.OfferStateInconsistent
[PARTIAL] TRLC Rootcause mw_com_fta.OsCreatesFileWithWrongName

OS creates file with wrong name


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:688:20

[PARTIAL] TRLC Rootcause mw_com_fta.OsRelatedFunctionalityFailed

OS related functionality failed


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:696:20

[PARTIAL] TRLC Rootcause mw_com_fta.OverwriteOfElementInUse
[PARTIAL] TRLC Rootcause mw_com_fta.ProxyCrashesWithoutUnsubscription

Proxy crashes without unsubscription


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:712:20

[PARTIAL] TRLC Rootcause mw_com_fta.ReferenceCountingFacilityForSampleptrIsBroken

Reference counting facility for SamplePtr is broken


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:744:20

[PARTIAL] TRLC Rootcause mw_com_fta.ReferencesInvalidMemory
[PARTIAL] TRLC Rootcause mw_com_fta.ReferencesValidMemoryInsideSHM

References valid memory inside shared-memory


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:760:20

[PARTIAL] TRLC Rootcause mw_com_fta.ReferencesValidMemoryOutsideSHM

References valid memory outside shared-memory


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:768:20

[PARTIAL] TRLC Rootcause mw_com_fta.RootCauseAllocatesAlreadyAllocatedMemory

Root Cause Allocates already allocated memory


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:784:20

[PARTIAL] TRLC Rootcause mw_com_fta.RootCauseDoesNotImplicitRemoveReceiveHandler

Root Cause Does not implicit remove receive handler


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:800:20

[PARTIAL] TRLC Rootcause mw_com_fta.RootCauseDoesNotSubscribe

Root Cause Does not subscribe


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:808:20

[PARTIAL] TRLC Rootcause mw_com_fta.RootCauseGetNewSamplesSucceedsDespiteAnError

Root Cause GetNewSamples succeeds despite an error


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:816:20

[PARTIAL] TRLC Rootcause mw_com_fta.RootCauseReturnsWrongFreeSampleCount

Root Cause Returns wrong free sample count


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:856:20

[PARTIAL] TRLC Rootcause mw_com_fta.RootCauseWrongStartFindServiceIsStopped

Wrong StartFindService is stopped


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:864:20

[PARTIAL] TRLC Rootcause mw_com_fta.RootCauseWronglyAlignedMemoryAllocated

Root cause: Wrongly aligned memory is sued


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:872:20

[PARTIAL] TRLC Rootcause mw_com_fta.SDClientMarkerFileNotFound
[PARTIAL] TRLC Rootcause mw_com_fta.SDClientMarkerFileWrongPath
[PARTIAL] TRLC Rootcause mw_com_fta.SDClientWrongMarkerFile

Service Discovery Client deletes wrong marker file


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:896:20

[PARTIAL] TRLC Rootcause mw_com_fta.SDFileDeletionFailure

Marker File Deletion Failure


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:904:20

[PARTIAL] TRLC Rootcause mw_com_fta.SDNotifyFailed
[PARTIAL] TRLC Rootcause mw_com_fta.SDNotifyWrongFD
[PARTIAL] TRLC Rootcause mw_com_fta.SHMObjectWrongPath
[PARTIAL] TRLC Rootcause mw_com_fta.ServiceInstanceUsageLockMechanismFailed

Service instance usage lock mechanism failed


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:944:20

[PARTIAL] TRLC Rootcause mw_com_fta.ServiceInstanceUsageNotChecked

Service instance usage not checked


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:952:20

[PARTIAL] TRLC Rootcause mw_com_fta.ServiceWasAlreadyOfferedByOurProcess

Service was already offered by our process


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:960:20

[PARTIAL] TRLC Rootcause mw_com_fta.ServiceWasAlreadyOfferedByPreviousDiedProcess

Service was already offered by previous died process


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:968:20

[PARTIAL] TRLC Rootcause mw_com_fta.ServiceWasOfferedButNotUnlikedOnStopOffer

Service was offered, but not unliked on stop offer


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:976:20

[PARTIAL] TRLC Rootcause mw_com_fta.ServiceWasOfferedByAnotherProcess

Service was offered by another process


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:984:20

[PARTIAL] TRLC Rootcause mw_com_fta.SharedMemoryIsOpenedEventhoughFileDoesNotExist

Shared Memory is opened eventhough file does not exist


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:992:20

[PARTIAL] TRLC Rootcause mw_com_fta.SharedMemoryObjectDoesNotExist

Shared Memory Object does not exist


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:1000:20

[PARTIAL] TRLC Rootcause mw_com_fta.SharedMemorySegmentDoesNotTryToCreateSegment

Shared Memory segment does not try to create segment.


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:1032:20

[PARTIAL] TRLC Rootcause mw_com_fta.SharedMemorySegmentIsNotUnlinked
[PARTIAL] TRLC Rootcause mw_com_fta.SharedMemorySegmentsAreCreatedUnderWrongName

Shared Memory segments are created under wrong name


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:1048:20

[PARTIAL] TRLC Rootcause mw_com_fta.SizeWasManipulatedInSharedMemory
[PARTIAL] TRLC Rootcause mw_com_fta.SizeWasWronglySetInSharedMemory
[PARTIAL] TRLC Rootcause mw_com_fta.SlotReferenceBrokenEGNonValid
[PARTIAL] TRLC Rootcause mw_com_fta.SlotReferenceCountNotDecremented
[PARTIAL] TRLC Rootcause mw_com_fta.UserMethodCallHandlerAssignmentWrong

User Handler assignment wrong


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:1152:20

[PARTIAL] TRLC Rootcause mw_com_fta.WatchesAreSetWrongly
[PARTIAL] TRLC Rootcause mw_com_fta.WritingStateChangeIsNotWorking

Writing State change is not working


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:1184:20

[PARTIAL] TRLC Rootcause mw_com_fta.WrongAcl
[PARTIAL] TRLC Rootcause mw_com_fta.WrongDirectoryStructure

Wrong Directory Structure


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:1208:20

[PARTIAL] TRLC Rootcause mw_com_fta.WrongMarkerFileName
[PARTIAL] TRLC Rootcause mw_com_fta.WrongMemoryResourceProxy

Wrong memory resource proxy


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:1224:20

[PARTIAL] TRLC Rootcause mw_com_fta.WrongName
[PARTIAL] TRLC Rootcause mw_com_fta.WrongNameOfSharedMemorySegment

Wrong name of shared memory segment


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:1240:20

[PARTIAL] TRLC Rootcause mw_com_fta.WrongPathResolvedFromInstanceidentifier

Wrong path resolved from InstanceIdentifier


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:1248:20

[PARTIAL] TRLC Rootcause mw_com_fta.WrongProvider
[PARTIAL] TRLC Rootcause mw_com_fta.WrongServiceDiscoveryMarkerFileSearchedFor

Wrong service discovery marker file searched for


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:1264:20

[PARTIAL] TRLC Rootcause mw_com_fta.WrongValueIsPassedToMessagePassingLibrary

Wrong value is passed to message passing library


Traces to:

  • missing reference to Safety Measures


Derived from:


Source: bazel-out/k8-fastbuild/bin/score/mw/com/dependability/safety_analysis/mw_com_safety_analysis/fta_events.trlc:1296:20

[OK] TRLC Rootcause mw_com_fta.ActivelyManipulateByProgrammParts
[OK] TRLC Rootcause mw_com_fta.AlgorithmicBug
[OK] TRLC Rootcause mw_com_fta.AllocateClaimsTooFewMemory
[OK] TRLC Rootcause mw_com_fta.ApiUsedInWrongContext
[OK] TRLC Rootcause mw_com_fta.BlocksOnCaller
[OK] TRLC Rootcause mw_com_fta.BrokenAllocator
[OK] TRLC Rootcause mw_com_fta.CallBlocksOnCallee
[OK] TRLC Rootcause mw_com_fta.CallBlocksOnUserHandler
[OK] TRLC Rootcause mw_com_fta.CallbackDangling
[OK] TRLC Rootcause mw_com_fta.CallbackIsNotStoredCorrectly
[OK] TRLC Rootcause mw_com_fta.ConsumerUsesAnOlderSlotThanHeAlreadyHasBlockedInThePreviousAccess
[OK] TRLC Rootcause mw_com_fta.DataTypeItselfIsAllocatedOnStack
[OK] TRLC Rootcause mw_com_fta.DifferentRevisionsForProxyAndSkeletonBuilt
[OK] TRLC Rootcause mw_com_fta.EventfqidWronglyConstructed
[OK] TRLC Rootcause mw_com_fta.FileCorrupted
[OK] TRLC Rootcause mw_com_fta.ForwardedTheWrongSharedMemorySegmentFromTheBeginning
[OK] TRLC Rootcause mw_com_fta.HoldsMoreSampleptrThanAnnounced
[OK] TRLC Rootcause mw_com_fta.HoldsMoreSampleptrThanConfigured
[OK] TRLC Rootcause mw_com_fta.InstanceSpecifierResolutionLogicBroken
[OK] TRLC Rootcause mw_com_fta.InternalApiUsed
[OK] TRLC Rootcause mw_com_fta.IssueInLockFreeSychronization
[OK] TRLC Rootcause mw_com_fta.JsonParserBroken
[OK] TRLC Rootcause mw_com_fta.LifeCycleIssuesSamplePtr
[OK] TRLC Rootcause mw_com_fta.LiteralyWrongNumberOfSlotsReserved
[OK] TRLC Rootcause mw_com_fta.ManipulateReadData
[OK] TRLC Rootcause mw_com_fta.MappingFromActualEventidToEventTypeIncorrect
[OK] TRLC Rootcause mw_com_fta.MiddlewareProvidedTypeIsWrong
[OK] TRLC Rootcause mw_com_fta.MissingSyncCodeAndConfiguration
[OK] TRLC Rootcause mw_com_fta.MoreThanOneSampleallocateeptrInParallel
[OK] TRLC Rootcause mw_com_fta.NecessarySizeCalculationRetrievesWrongValue
[OK] TRLC Rootcause mw_com_fta.OffsetPtrCorruption
[OK] TRLC Rootcause mw_com_fta.OmitReadingOfRelevantElements
[OK] TRLC Rootcause mw_com_fta.OrderingWrong
[OK] TRLC Rootcause mw_com_fta.ProxyIdOverwritten
[OK] TRLC Rootcause mw_com_fta.PtrDangling
[OK] TRLC Rootcause mw_com_fta.ReceiveErrorOnRegistration
[OK] TRLC Rootcause mw_com_fta.RetryLogicNotBulletProof
[OK] TRLC Rootcause mw_com_fta.RootCauseAnyFunctionBlocksLongerThanExpected
[OK] TRLC Rootcause mw_com_fta.RootCauseReceiveHandlerInvokedMultipleTimes
[OK] TRLC Rootcause mw_com_fta.RootCauseReceiveHandlerInvokedWithWrongEvent
[OK] TRLC Rootcause mw_com_fta.RootCauseReceiveHandlerInvokedWithoutEventNotification
[OK] TRLC Rootcause mw_com_fta.RootCauseReceiveHandlerNotInvoked
[OK] TRLC Rootcause mw_com_fta.ServerProcessCrash
[OK] TRLC Rootcause mw_com_fta.SharedMemoryResourceOpensWrongSharedMemorySegment
[OK] TRLC Rootcause mw_com_fta.SharedMemoryResourceReturnsWrongProxy
[OK] TRLC Rootcause mw_com_fta.SharedMemoryRessourceNotForwarded
[OK] TRLC Rootcause mw_com_fta.SharedMemoryTruncationFails
[OK] TRLC Rootcause mw_com_fta.SharedmemoryfactoryReturnsWrongMemoryRessource
[OK] TRLC Rootcause mw_com_fta.SlotAllocationSynchronisationWrongState
[OK] TRLC Rootcause mw_com_fta.SlotAllocationSynchronisationWrongTimestamp
[OK] TRLC Rootcause mw_com_fta.StaticCreateFunctionReturnsAnError
[OK] TRLC Rootcause mw_com_fta.TerminatingUserCallback
[OK] TRLC Rootcause mw_com_fta.TooMuchMemoryAllocated
[OK] TRLC Rootcause mw_com_fta.UserFehler
[OK] TRLC Rootcause mw_com_fta.UserProvidedTypeIsWrong
[OK] TRLC Rootcause mw_com_fta.UserProvidedWrongConfiguration
[OK] TRLC Rootcause mw_com_fta.WrongAclConfigurationForShmSegments
[OK] TRLC Rootcause mw_com_fta.WrongSlotReferenced
[OK] TRLC Rootcause mw_com_fta.WrongValueInsertedSlotStatus